R3303-HP HSR6800 Routers Fundamentals Command Reference

168
Field Remarks
Module not ready Module is not ready.
APD supply fault APD (Avalanche Photo Diode) supply fault.
TEC fault TEC (Thermoelectric Cooler) fault.
Wavelength unlocked
Wavelength of optical signal exceeds the manufacturer's
tolerance.
Temp high Temperature is high.
Temp low Temperature is low.
Voltage high Voltage is high.
Voltage low Voltage is low.
Transceiver info I/O error Transceiver information read and write error.
Transceiver info checksum error Transceiver information checksum error.
Transceiver type and port configuration
mismatch
Transceiver type does not match port configuration.
Transceiver type not supported by port
hardware
Transceiver type is not supported on the port.
Examples
# Display the alarms existing on the transceiver module in interface GigabitEthernet 3/0/1.
<Sysname> display transceiver alarm interface gigabitethernet 3/0/1
GigabitEthernet3/0/1 transceiver current alarm information:
RX loss of signal
RX power low
Table 27 Command output
Field Descri
p
tion
transceiver current alarm information Alarms existing on the transceiver module.
RX loss of signal Incoming (RX) signal is lost.
RX power low Incoming (RX) power level is low.
display transceiver diagnosis
Use display transceiver diagnosis to display the current measured values of the digital diagnosis
parameters for transceiver modules.
Syntax
display transceiver diagnosis { controller [ controller-type controller-number ] | interface [ interface-type
interface-number ] } [ | { begin | exclude | include } regular-expression ]
Views
Any view
Default command level
2: System level