R3303-HP HSR6800 Routers High Availability Command Reference
17
• display oam link-event
• display oam configuration
oam errored-frame-period period
Use oam errored-frame-period period to set the errored frame period event detection interval.
Use undo oam errored-frame-period period to restore the default.
Syntax
oam errored-frame-period period period-value
undo oam errored-frame-period period
Default
The errored frame period event detection interval is 1000 milliseconds.
Views
System view
Default command level
2: System level
Parameters
period-value: Errored frame period event detection interval in the range of 100 to 60000 (in
milliseconds).
Usage guidelines
As for errored frame period event detection, the system first uses the following expression to convert the
errored frame period event detection interval to the maximum number of 64-byte frames that can be
transmitted through an Ethernet port in the period:
bandwidth * period / (64 * 8 * 1000),
where bandwidth is the port bandwidth (in bps) and "period" is the configured period (in milliseconds).
Examples
# Set the errored frame period event detection interval to 10 seconds (10000 milliseconds).
<Sysname> system-view
[Sysname] oam errored-frame-period period 10000
Related commands
• oam errored-frame-period threshold
• display oam link-event
• display oam configuration
oam errored-frame-period threshold
Use oam errored-frame-period threshold to set the errored frame period event triggering threshold.
Use undo oam errored-frame-period threshold to restore the default.