R3303-HP HSR6800 Routers High Availability Command Reference
18
Syntax
oam errored-frame-period threshold threshold-value
undo oam errored-frame-period threshold
Default
The errored frame period event triggering threshold is 1.
Views
System view
Default command level
2: System level
Parameters
threshold-value: Errored frame period event triggering threshold in the range of 0 to 4294967295.
Examples
# Set the errored frame period event triggering threshold to 100.
<Sysname> system-view
[Sysname] oam errored-frame-period threshold 100
Related commands
• oam errored-frame-period period
• display oam link-event
• display oam configuration
oam errored-frame-seconds period
Use oam errored-frame-seconds period to set the errored frame seconds event detection interval.
Use undo oam errored-frame-seconds period to restore the default.
Syntax
oam errored-frame-seconds period period-value
undo oam errored-frame-seconds period
Default
The errored frame seconds event detection interval is 60 seconds.
Views
System view
Default command level
2: System level
Parameters
period-value: Errored frame seconds event detection interval in the range of 10 to 900 (in seconds).
Examples
# Set the errored frame seconds event detection interval to 100 seconds.
<Sysname> system-view