R3303-HP HSR6800 Routers Interface Configuration Guide
29
For each channel set, the system automatically creates a serial interface named serial
interface-number:set-number. These interfaces are logically equivalent to synchronous serial interfaces
where you can make other configurations such as:
• Data link protocol such as PPP and FR
• IP addressing
Configuring other CE1 interface parameters
Step Command Remarks
1. Enter system view.
system-view N/A
2. Enter CE1 interface view.
controller e1 number N/A
3. Configure the interface
description.
description text
Optional.
By default, the description of an
interface is interface-name
Interface.
4. Set the physical state change
suppression interval on the CE
1 interface.
link-delay delay-time
By default, physical state change
suppression is disabled.
5. Set the line code format.
code { ami | hdb3 }
Optional.
The default is high density bipolar
3 (HDB3).
6. Enable AIS (alarm indication
signal) test.
detect-ais
Optional.
By default, AIS test is performed.
7. Set the cable type.
cable { long | short }
Optional.
The default cable setting is long
mode.
8. Set the clock mode.
clock { master | slave }
Optional.
The default clock mode is slave,
which is line clock.
9. Enable automatic clock mode
change.
clock-change auto
Optional.
Disabled by default.
10. Set the framing format.
frame-format { crc4 | no-crc4 }
Optional.
The default is no-CRC4.
11. Set the line idle code type.
idlecode { 7e | ff }
Optional.
The default is 0x7E.
12. Set the type of interframe
filling tag.
itf type { 7e | ff }
Optional.
The default is 0x7E.
13. Set the number of interframe
filling tags.
itf number number
Optional.
The default is 4.
14. Set the loopback mode.
loopback { local | payload |
remote }
Optional.
Loopback is disabled by default.