R3303-HP HSR6800 Routers Interface Configuration Guide

31
Task Command Remarks
Clear the controller counter for a
CE1 interface.
reset counters controller e1
interface-number
Available in user view.
Configuring a CT1 interface
A CT1 interface can operate only in channelized mode. When it is working as a CT1 interface, all the
timeslots (numbered 1 to 24) can be randomly divided into groups. Each of these groups can form one
channel set for which the system automatically creates an interface logically equivalent to a synchronous
serial interface. This interface supports link layer protocols such as PPP, HDLC, and FR, and network
protocol IP.
Configuring a CT1 interface in CT1 mode
Step Command Remarks
1. Enter system view.
system-view N/A
2. Enter CT1 interface view.
controller t1 number N/A
3. Bundle timeslots on the
interface into a channel set.
channel-set set-number timeslot-list
list [ speed { 56k | 64k } ]
Up to 24 channel sets can be
bundled.
The default timeslot speed is 64
kbps.
4. Set other interface
parameters.
See "Configuring other CT1
interface parameters."
Optional.
For each channel set, the system automatically creates a serial interface named serial number:set-number.
This interface is logically equivalent to a synchronous serial interface where you can make other
configurations about:
Data link protocol such as PPP and FR
IP addressing
Configuring other CT1 interface parameters
Step Command Remarks
1. Enter system view.
system-view N/A
2. Enter CT1 interface view.
controller t1 number N/A
3. Configure the interface
description.
description text
Optional.
By default, the description of an
interface is interface-name
Interface.
4. Set the physical state change
suppression interval on the CT
1 interface.
link-delay delay-time
By default, physical state change
suppression is disabled.