R3303-HP HSR6800 Routers Interface Configuration Guide
55
# Configure frame relay encapsulation on the interface.
[RouterB-Pos2/1/0] link-protocol fr
[RouterB-Pos2/1/0] fr interface-type dte
[RouterB-Pos2/1/0] ip address 10.10.10.2 255.255.255.0
[RouterB-Pos2/1/0] fr dlci 70
[RouterB-Pos2/1/0] fr map ip 10.10.10.1 70
[RouterB-Pos2/1/0] mtu 1500
3. Configure Router C in the same way Router B is configured.
Verifying the configuration
Check interface connectivity with the display interface pos command and test network connectivity with
the ping command.
Troubleshooting POS interfaces
Symptom 1
The physical state of POS interface is down.
Solution
• Check that the transmitting and receiving fibers-optic are correctly connected to the POS interface.
If you connect the two ends of a fiber-optic to the transmitting end and the receiving end of the same
POS interface, when you execute the display interface command, a "loopback detected" message
is displayed on the screen even if loopback is not enabled.
• If the two routers are directly connected back to back, check that the internal clock is enabled on
either of the two POS interfaces.
Symptom 2
The physical layer is up but the link is down.
Solution
Check the following items:
• The configurations of clock mode, scrambling, and other physical parameters are consistent on the
connected two POS interfaces.
• The same link layer protocol is configured on two sides.
Symptom 3
A great amount of IP packets are dropped.
Solution
Check that the correct clock mode is configured on the POS interface. If not, enormous amount of CRC
errors can be generated.