# Create reaction entry 1 for monitoring the average destination-to-source jitter of UDP jitter packets. Set
the upper threshold to 50 milliseconds, and the lower threshold to 5 milliseconds. Before the NQA
operation starts, the initial state of the reaction entry is invalid. After the operation, the average
destination-to-source jitter is checked. If it exceeds the upper threshold, the state of the reaction entry is
set to over-threshold. If it is below the lower threshold, the state is set to below-threshold. Once the state
of the reaction entry changes, a trap message is generated and sent to the NMS.
<Sysname> system-view
[Sysname] nqa entry admin test
[Sysname-nqa-admin-test] type udp-jitter
[Sysname-nqa-admin-test-udp-jitter] reaction 1 checked-element jitter-ds threshold-type
average threshold-value 50 5 action-type trap-only
# Create reaction entry 2 for monitoring the destination-to-source jitter of UDP jitter probe packets. Set
the upper threshold to 50 milliseconds, and the lower threshold to 5 milliseconds. Before the NQA
operation starts, the initial state of the reaction entry is invalid. After the operation, the
destination-to-source jitter is checked against the threshold range. If the total number of threshold
violations exceeds 100 (included), the state of the entry is set to over-threshold. Otherwise, the state of the
entry is set to below-threshold. Once the state of the reaction entry changes, a trap message is generated
and sent to the NMS.
<Sysname> system-view
[Sysname] nqa entry admin test
[Sysname-nqa-admin-test] type udp-jitter
[Sysname-nqa-admin-test-udp-jitter] reaction 2 checked-element jitter-ds threshold-type
accumulate 100 threshold-value 50 5 action-type trap-only
reaction checked-element mos
Use reaction checked-element mos to configure a reaction entry for monitoring the MOS value in the
NQA operation. You cannot edit a reaction entry. To change the attributes in a reaction entry, use undo
reaction to delete the entry first and then configure a new one.
Use undo reaction to delete the specified reaction entry.
Syntax
reaction item-number checked-element mos threshold-value upper-threshold lower-threshold
[ action-type { none | trap-only } ]
undo reaction item-number
Default
No reaction entry for monitoring the MOS value is configured.
Views
Voice operation view
Default command level
2: System level
Parameters
item-number: Specifies a reaction entry ID in the range of 1 to 10.
threshold-value: Specifies threshold values.