R3303-HP HSR6800 Routers Network Management and Monitoring Command Reference
74
Field Descri
p
tion
local mode
Operation mode of the local device:
• unspec—The mode is unspecified.
• active—Active mode.
• passive—Passive mode.
• client—Client mode.
• server—Server mode.
• bdcast—Broadcast server mode.
• control—Control query mode.
• private—Private message mode.
local poll
Poll interval of the local device, in seconds. The value displayed is a
power of 2. For example, if the displayed value is 6, the poll interval
of the local device is 2
6
, or 64 seconds.
peer mode
Operation mode of the peer device:
• unspec—The mode is unspecified.
• active—Active mode.
• passive—Passive mode.
• client—Client mode.
• server—Server mode.
• bdcast—Broadcast server mode.
• control—Control query mode.
• private—Private message mode.
peer poll
Poll interval of the peer device, in seconds. The value displayed is a
power of 2. For example, if the displayed value is 6, the poll interval
of the local device is 2
6
, or 64 seconds.
offset
Offset of the system clock relative to the reference clock, in
milliseconds.
delay
Roundtrip delay from the local device to the clock source, in
milliseconds.
disper Maximum error of the system clock relative to the reference clock.
root delay
Roundtrip delay from the local device to the primary reference
source, in milliseconds.
root disper
Maximum error of the system clock relative to the primary reference
clock, in milliseconds.
reach
Reachability count of the clock source. 0 indicates that the clock
source is unreachable.
sync dist
Synchronization distance relative to the upper-level clock, in
seconds, and calculated from dispersion and roundtrip delay
values.
sync state
State of the state machine.
The displayed value is an integer in the range of 0 to 5.
precision Precision of the system clock.
version
NTP version.