HP HSR6802 HSR6804 HSR6808 Routers Installation Guide

68
PALM LED is steady on
If the PALM LED of the MPU is steady on, it indicates that exceptions have occurred to the power supply
system. The following reasons might apply:
Mismatch between the power supply and power consumption. For example, if an HSR6808 is
installed with a 650 W power module but two SAP-48GBE modules, the power available is not
sufficient for the whole power consumption and one SAP module cannot be powered on.
Intermixing of AC and DC power modules and different specifications of the inserted power
modules.
To solve the problem, examine the output for the above reasons on the serial terminal and the software
management tool.
If the problem persists, record the above information, and contact your local sales agent.
Table 20 MPU LEDs
LED Status Descri
p
tion
RUN (green)
Off No power is provided or the MPU is faulty.
Flashing slowly at 1 Hz
The MPU is operating correctly.
Flashing fast at 8 Hz
The MPU is loading application programs or the MPU is not
working.
To avoid the hardware damage, do not power off the router
or insert or remove the MPU when the MPU is loading
application programs.
ACT (green)
Off The MPU is in standby state.
Steady on The MPU is in active state.
PALM (red)
Off The power supply is operating correctly.
Steady on
The power for use is not sufficient, or power modules of
different specifications are inserted.
ALM (red)
Off The system is operating correctly without any alarm.
Steady on The system is faulty. You must view the system logs.
Flashing fast at 8 Hz The system is seriously faulty. An immediate action is needed.
LPU failures
RUN LED is off
If the RUN LED of the LPU is off, it indicates that the LPU is powered off or faulty.
To troubleshoot the LPU failure:
1. Verify that the router is powered on.
2. If the router is powered on, verify that the LPU is correctly inserted in a slot.