R3303-HP HSR6800 Routers High Availability Configuration Guide

13
Ste
p
Command
Remarks
1. Enter system view.
system-view N/A
2. Configure the Ethernet OAM
handshake packet
transmission interval.
oam timer hello interval
Optional.
1000 milliseconds by default.
3. Configure the Ethernet OAM
connection timeout timer.
oam timer keepalive interval
Optional.
5000 milliseconds by default.
Configuring link monitoring
After Ethernet OAM connections are established, the link monitoring periods and thresholds configured
in this section automatically take effect on all Ethernet ports.
Configuring errored symbol event detection
An errored symbol event occurs when the number of detected symbol errors during a specific detection
interval exceeds the predefined threshold.
To configure errored symbol event detection:
Ste
p
Command
Remarks
1. Enter system view.
system-view N/A
2. Configure the errored
symbol event detection
interval.
oam errored-symbol period period-value
Optional.
1 second by default.
3. Configure the errored
symbol event triggering
threshold.
oam errored-symbol threshold
threshold-value
Optional.
1 by default.
Configuring errored frame event detection
An errored frame event occurs when the number of detected error frames during a specific interval
exceeds the predefined threshold.
To configure errored frame event detection:
Ste
p
Command
Remarks
1. Enter system view.
system-view N/A
2. Configure the errored
frame event detection
interval.
oam errored-frame period period-value
Optional.
1 second by default.
3. Configure the errored
frame event triggering
threshold.
oam errored-frame threshold
threshold-value
Optional.
1 by default.