HyperFabric Release Notes

HyperFabric Release Notes
Known Problems and Workarounds
Chapter 18
Known Problems and Workarounds
The known problems and corresponding workarounds for versions B.11.31.01 of the
HyperFabric software are as follows:
HyperFabric initialization may fail if the STRMSGSZ kernel parameter is set.
WORKAROUND: Set STRMSGSZ to 0 on /stand/system from the command line to unset
the parameter.
In SMH, set STRMSGSZ to 0 (zero) to unset the parameter.
The switch management software in HyperFabric has some problems that may result in
the following symptoms:
The HyperFabric management daemon (clic_mgmtd) loses connection with other
nodes in the cluster.
Invalid class messages (that is, class messages that are not related to HyperFabric)
get logged into the /var/adm/clic_log global log file.
WORKAROUND: Disconnect the HyperFabric switch(es) from the Ethernet network,
and leave them disconnected. Then, reconfigure HyperFabric by doing one of the
following:
Use the clic_init -c command, but do not configure switch management.
Use SMH (HP-UX 11i v3). As mentioned earlier, you cannot configure switch
management within SMH.
HyperFabric will work correctly without switch management configured, but the switches
will not create diagnostic logs.
When you run the clic_probe nodename -c adapter_ID command, if the adapter
specified by adapter_ID is not operationaland another (operational) adapter is
installed in the source node (the node you specified the clic_probe command
from)clic_probe uses the other adapter. However, clic_probe does not notify you that
the adapter you specified is not operational.
HP-UX 11i v3 installation issue on systems that have HyperFabric cards. Customers
installing or re-installing HP-UX 11i v3 using the Guided Installation option may
encounter a program loop during network configuration the first time the system reboots.
This is not due to a defective card.