5.5 HP StorageWorks X9300 Network Storage Gateway Administrator Guide (AW539-96007, March 2011)

Table Of Contents
8. Enable standby pairing and monitoring on the new HBA if desired, using the GUI or CLI:
On the GUI, select Servers from the Navigator pane, and then select the appropriate server
from the Servers pane. Select HBAs in the left pane, select the appropriate Node WWN, and
click Modify. On the Modify HBA Properties window, select Enable monitoring and Enable
backup pair, and select the WWPN for the backup HBA.
On the CLI, execute the following command to enable standby pairing:
ibrix_hba -b -P WWPN1:WWPN2 -h <server_name>
Execute the following command on both ports to enable monitoring:
ibrix_hba -m -h <server_name> -p WWPN
9. Fail back the server using the GUI or CLI:
On the GUI, select Servers from the Navigator pane, and then select the appropriate server
from the Servers pane. Next, select the server name in the left pane, and click Failback.
On the CLI, execute the following command:
ibrix_server -f –U –h <server_name>
X9300 Network Storage Gateway Administrator Guide 105