6.3 HP StoreAll 9300/9320 Storage Administrator Guide (AW549-96072, June 2013)

5. If file systems are mounted from a Windows StoreAll client, unmount the file systems using the
Windows client GUI.
6. Unmount all StoreAll file systems:
<ibrixhome>/bin/ibrix _umount -f <fsname>
Saving the node configuration
Complete the following steps on each node, starting with the node hosting the active management
console:
1. Run /usr/local/ibrix/setup/save_cluster_config. This script creates a tgz file
named <hostname>_cluser_config.tgz, which contains a backup of the node
configuration.
2. Save the <hostname>_cluser_config.tgz file, which is located in /tmp, to the external
storage media.
Performing the upgrade
Complete the following steps on each node:
1. Obtain the latest Quick Restore image from the HP kiosk at http://www.software.hp.com/
kiosk (you will need your HP-provided login credentials).
2. Burn the ISO image to a DVD.
3. Insert the Quick Restore DVD into the server DVD-ROM drive.
4. Restart the server to boot from the DVD-ROM.
5. When the StoreAll Network Storage System screen appears, enter qr to install the StoreAll
software on the file serving node.
The server reboots automatically after the software is installed. Remove the DVD from the
DVD-ROM drive.
Restoring the node configuration
Complete the following steps on each node, starting with the previous active management console:
1. Log in to the node. The configuration wizard should pop up. Escape out of the configuration
wizard.
2. Attach the external storage media containing the saved node configuration information.
3. Restore the configuration. Run the following restore script and pass in the tgz file containing
the node's saved configuration information as an argument:
/usr/local/ibrix/setup/restore <saved_config.tgz>
4. Reboot the node.
Completing the upgrade
Complete the following steps:
1. Remount all StoreAll file systems:
<ibrixhome>/bin/ibrix_mount -f <fsname> -m </mountpoint>
2. Remount all previously mounted StoreAll file systems on Windows StoreAll clients using the
Windows client GUI.
3. If automated failover was enabled before the upgrade, turn it back on from the node hosting
the active management console:
<ibrixhome>/bin/ibrix_server -m
4. Confirm that automated failover is enabled:
<ibrixhome>/bin/ibrix_server -l
In the output, HA should display on.
Upgrading the StoreAll software to the 5.6 release 165