6.3 HP StoreAll 9300/9320 Storage Administrator Guide (AW549-96072, June 2013)

The NICs panel for the ib69s2, the backup server, shows that bond0:1 is an inactive, standby
NIC and bond0:2 is an active NIC.
Changing the HA configuration
To change the configuration of a NIC, select the server on the Servers panel, and then select NICs
from the lower Navigator. Click Modify on the NICs panel. The General tab on the Modify NIC
Properties dialog box allows you change the IP address and other NIC properties. The NIC HA
tab allows you to enable or disable HA monitoring and failover on the NIC and to change or
remove the standby NIC. You can also enable link state monitoring if it is supported on your cluster.
See “Configuring link state monitoring for iSCSI network interfaces” (page 50).
To view the power source for a server, select the server on the Servers panel, and then select Power
from the lower Navigator. The Power Source panel shows the power source configured on the
server when HA was configured. You can add or remove power sources on the server, and can
power the server on or off, or reset the server.
60 Configuring failover