HP Intelligent Management Center v5.1 SP1 Application Manager Administrator Guide

324
PasswordThis field appears only when you select WMI for Monitor Type. Enter the password
of the administrator.
Directory NameEnter the absolute path and name of the directory you want to monitor. Use
the C:\Windows format for Windows, or the /home/Apache format for Linux and UNIX.
ContactEnter the contact information, such as name, email address, and telephone number.
Related ApplicationsClick Add. The Select Applications window appears. Select the
applications that the directory depends on, and click OK. You cannot select operating system
applications, such as Windows XP, Windows Server, AIX, FreeBSD, OpenBSD, HP-UX,
Solaris, Mac OS, and Linux. You can view the dependencies between applications in a
topology view.
Detect ApplicationEnable or disable application detection. Application detection enables
APM to verify connection to the application by using the previous parameter settings, and to
determine whether to add the application monitor based on the verification result. APM adds
the application monitor only when it can connect to the application. If you do not select this
parameter, APM will add the application monitor without verifying the connection.
5. Click OK.
Modifying a directory application monitor
Operators can modify all parameters except the IP address of a directory application monitor. If the IP
address of the host where the monitored directory is located changes, operators must add a new
application monitor for the directory.
1. Click the Resource tab.
2. Select Application Manager > Application Monitor from the navigation tree.
The application monitor list page displays all application monitors.
3. Click the Modify icon for the directory monitor you want to modify.
The page for modifying the directory application monitor appears.
4. Modify the following parameters for the application monitor:
NameEnter the application monitor name, which must be unique in APM. HP recommends
that you use the Application name_host IP address format to name the application monitor.
DescriptionEnter a description for the application monitor to aid maintenance.
IP AddressThis field cannot be modified.
Polling Interval (min)Select a polling interval for the application monitor. Available options
include 1, 2, 3, 4, 5, 10, 20, and 30. The default polling interval is 5 minutes. A shorter
polling interval provides more accurate real-time data, but requires higher performance.
Monitor TypeSelect a monitor type for the application monitor. Monitor types include WMI
and CLI.
UsernameThis field appears only when you select WMI for Monitor Type. Enter the username
of the Windows administrator.
If the administrator is a domain user, use the domain name\username format.
If the administrator is a local user, use the host name\username or IP address\username
format, or simply use the username.
PasswordThis field appears only when you select WMI for Monitor Type. Enter the password
of the administrator.