HP Intelligent Management Center v5.1 SP1 Application Manager Administrator Guide

33
UnitSpecify the unit for the threshold, its value is depended on the monitor index type.
Specially, some index does not have a unit, such as the physical thread count of .Net server.
Enable Level-1 ThresholdEnable or Disable the Level-1 threshold for the monitor index.
Threshold Specify the threshold condition, APM will activate the related major alarm
when the monitor index meets the threshold.
Enable Level-2 ThresholdEnable or Disable the Level-2 threshold for the monitor index.
Threshold Specify the threshold condition, APM will activate a related critical alarm
when the monitor index meets the threshold.
5. Click OK.
Port Configuration
APM provides you a default monitor port for each application. With the monitor port, APM can find the
applications automatically in the host. But, to those applications that dont have a default port,
operators should set the port value through Port Configuration.
The port we mentioned here is a monitor port but not a service port, it makes APM available to get
monitor index from the applications. Table 7 lists the monitor ports predefined in the APM, some of
them are the same one with the service port, such as SQL Server-1433MySQL-3306Oracle-1521
Apache-80.
Table 7 Application monitor port list
Application Type
Monitor Mode
Monitor Port
Linux CLI
Get access to the remote operating system and obtain the
monitor index value by using Telnet/SSH.
Telnet-23
SSH-22
Solaris
Mac OS
AIX
HP-UX
OpenBSD
FreeBSD
Exchange 2003 WMI
Get the monitor index value by using the Windows
Management Instrume (WMI). It is applicable to be used
when APM is installed in the Windows+SQL Server or
Windows+MySQL.
WMI-135
Exchange 2007
Windows Server
Windows XP
.NET Server
Active Directory Service
IIS Server
Tomcat Server JMX
Get the monitor index value by using the Java
Management Extensions.
JMX-1099
JBoss Server
SQL Server Service Port SQL Server-1433