HP Intelligent Management Center v5.2 Application Performance Manager Administrator Guide

381
IP AddressCannot be modified.
NameModify the unique application monitor name. HP recommends using Application
name_host IP address for naming the application monitor.
DescriptionModify description for the application monitor.
PortModify the HTTP port used by the RESTful Web service.
Traffic Collection PortModify the port used by the RESTful Web service to provide services.
This field appears only after at least one probe is configured for APM.
Polling Interval (min)Select a polling interval for the application monitor. Available options
include 1, 2, 3, 4, 5, 10, 20, and 30. The default polling interval is 5 minutes. A shorter polling
interval provides more accurate real-time data, but consumes more system resources.
Username/PasswordModify the username and password used to access the RESTful Web
service if the service requires identity authentication.
PathModify the URL for the RESTful Web service. Do not include the IP address or port
information in the URL. APM determines whether the RESTful Web service is available by
accessing the specified URL.
ContactModify the contact information, such as name, email address, and telephone
number. The default is the username of the operator who created the application monitor.
Related ApplicationsModify the applications that the Restful Web service depends on. Click
Add, and then select applications in the popup Select Applications window. Operating system
applications, such as Windows, AIX, FreeBSD, OpenBSD, HP-UX, Solaris, Mac OS, and Linux,
cannot be selected. APM automatically adds the dependencies between the Restful Web
service and operating system applications by IP address and displays their dependencies in the
application topology. To remove dependencies between the Restful Web service and one or
more applications, select the target applications in the Related Applications box and click
Delete.
Detect ApplicationSelect this parameter if you want to enable application detection.
Application detection enables APM to verify connection to the application by using the previous
parameter settings, and to determine whether to modify the application monitor based on the
verification result. APM modifies the application monitor only when it can connect to the
application. When this parameter is not selected, APM modifies the application monitor without
verifying the connection.
5. Click OK.
Viewing the RESTful Web service application monitor report
After adding the RESTful Web service application monitor, APM collects application index data to
calculate its availability and health status. Obtain monitor indexes for the RESTful Web service by
viewing the monitor report.
To access the RESTful Web service application monitor report:
1. Click the Resource tab.
2. Select Application Manager > Application Monitor from the navigation tree.
The application monitor list page displays all application monitors.
3. Click the name link of a RESTful Web service application monitor.
The monitor report of RESTful Web service appears, as shown in Figure 323. For information
about the icons in the monitor report, see "2 Quick start." This section describes the fields in each
area of the monitor report.