HP Intelligent Management Center v5.2 Application Performance Manager Administrator Guide
39
Index/Threshold Type—Click Select and select an application monitor index from the popup
window. The name of the selected monitor index automatically populates the Index field, and
the type of the selected monitor index automatically populates the Threshold Type field. The
monitor index type can be Value or String.
Threshold Condition—Select a threshold condition from the list. The available options vary with
the monitor index type. For the Value type, options are Greater than or equal to and Less than
or equal to. For the String type, options are Include and Exclude.
Unit—Select a unit type from the list. The value depends on the monitor index type. Some
indexes do not contain a unit type, such as the physical thread count of a .NET server.
Enable Level-1 Threshold/Threshold—Configure the level-1 threshold setting for the monitor
index. If you enable the Level-1 threshold, set a level-1 threshold value in the Threshold field.
APM activates a major alarm when the monitor index meets the threshold.
Enable Level-2 Threshold/Threshold—Configure the level-2 threshold setting for the monitor
index. If you enable the Level-2 threshold, set a level-2 threshold value in the Threshold field.
APM activates a critical alarm when the monitor index meets the threshold.
6. Click OK.
Modifying a global threshold
To modify a predefined or user-defined global threshold:
1. Click the Resource tab.
2. Select Application Manager > Configurations from the navigation tree.
The Configurations page appears.
3. Click Threshold Configuration.
The Global Threshold List appears.
4. Click the Modify icon for the threshold you want to modify.
The Modify Threshold page appears.
5. Modify parameters as needed:
Application Type—Cannot be modified.
Index—Cannot be modified.
Threshold Type—Cannot be modified.
Threshold Condition—Modify the threshold condition. The available options vary with the
monitor index type. For the Value type, options are Greater than or equal to and Less than or
equal to. For the String type, options are Include and Exclude.
Unit—Modify the threshold unit type. The value depends on the monitor index type. Some
indexes do not contain a unit type, such as the physical thread count of a .NET server.
Enable Level-1 Threshold/Threshold—Modify the level-1 threshold setting for the monitor index.
You can modify the level-1 threshold value or disable the level-1 threshold as needed.
Enable Level-2 Threshold/Threshold—Modify the level-2 threshold setting for the monitor index.
You can modify the level-2 threshold value or disable the level-2 threshold as needed.
6. Click OK.