3. Select SPB devices from the device list.
4. Click Delete.
5. Click OK.
Configuring the MST region parameters
SPBM runs on MSTI 4092. For two SPB neighbors to establish an adjacency, you must activate
MSTI 4092 on both of them and make sure their in-between link has connectivity. To forward traffic
to the link, you must also configure the same MST region parameters on the devices, including:
Format selector. The value for this parameter is fixed at 0.
Region name.
Revision level.
VLAN-to-MSTI mapping table.
Configuring MST region parameters for one device
To configure the MST region parameters for one device:
1. From the navigation tree, select Service > VAN Fabric Manager > LAN Configuration > SPB.
2. Click the Device Management tab.
3. Click the Operation icon for a device in the Operation column.
4. Select Set MST Region.
5. Configure the MST region parameters:
MST Region—MST region name.
B-VLAN ID—B-VLAN IDs mapped to MSTI 4092.
MSTP Revision Level—Revision number of the configuration.
6. Click OK.
Configuring MST region parameters for multiple devices
To configure the MST region parameters for multiple devices:
1. From the navigation tree, select Service > VAN Fabric Manager > LAN Configuration > SPB.
2. Click the Device Management tab.
3. Select SPB devices from the device list.
4. Click Set MST Region.
5. Configure the MST region parameters:
MST Region—MST region name.
B-VLAN ID—B-VLAN IDs mapped to MSTI 4092.
MSTP Revision Level—Revision number of the configuration.
6. Click OK.
Managing interfaces
The SPB module provides the following interface management functions:
Viewing the interface list
Querying interfaces
Viewing interface details
Enabling or disabling SPBM on interfaces
92 Managing SPB