HP Insight Cluster Management Utility v7.1 User Guide

2.1.7.4 SL2x170z G6 and DL170h G6 Servers BIOS setting
IMPORTANT: To enable BIOS updates, you must restart the server. You can restart the server
with Ctrl+Alt+Delete immediately after leaving the BIOS, or you can physically restart the server
by using the power switch on the server.
Figure 3 NIC2 on the SL2x170z G6 Server
BIOS settings
Post speedup Enabled
Numlock Enabled
Restore after AC loss Last state
Post F1 prompt Delayed
CPU setup
Proc hyper threading Disabled
IDE configuration
SATA controller mode AHCI
Drive cache Enabled
IDE timeout 35
Chipset ACPI configuration
High Performance Event timer Enabled
IPMI serial port configuration
Serial port assignment BMC
Serial port switching Enabled
Serial port connection mode Direct
LAN configuration
If your node is wired with the LO100i management port shared with NIC2:
BMC NIC Allocation Shared
LAN protocol: HTTP, telnet, ping Enabled
18 Installing and upgrading HP Insight CMU