HP Insight Control Server Provisioning 7.3 Update 1 Administrator Guide

Server is in WinPE after capture image
Possible cause and resolutionSymptom
This is the expected behavior. You will need to deploy the
image you just captured back to the reference server.
The target server is left in the WinPE service OS after the
capture image Build Plan is run.
Windows image capture and install limitations
Possible cause and resolutionSymptom
The target server must have similar hardware to the reference
server from where the image was captured from. Before you
Windows image deploy fails.
use the image tool to install a Windows image, we
recommend that you review the ImageX documentation.
http://technet.microsoft.com/en-us/library/cc722145%28v=ws.10%29.aspx
Image deploy fails with missing WIMFileName
Possible cause and resolutionSymptom
The custom attribute WimFileName must be defined. This
custom attribute specifies the file name for the WIM image
Windows image deploy fails with missing WIMFileName.
you are creating or installing. Images will always be located
in the Images folder on your Media Server unless you modify
the parameters to the Windows Image Capture and
Windows Image Deploy Build Plan steps to use another
folder.
Boot step failures
Boot step error: Problem manipulating EV
Possible cause and resolutionSymptom
The Boot step is trying to set the one-time boot either during
its Power On Self Test or while the server is in the RBSU,
Boot step error: Problem manipulating EV.
which is not permitted. Power off the target server prior to
running the Build Plan by connecting to the iLO via a
browser and selecting “Press and Hold” under the Power
Management options.
Add server fails with ILO_WRITE_BLOB_STORE_FAILURE on iLO 1.20 FW
Possible cause and resolutionSymptom
Details: An error occurred while performing writeBlobStore
operation.
On rare occasions, the Boot step of a Build Plan may fail
on Gen8 servers. with the following error.
Cause: [iLO (10.9.1.33)] Error : Internal error.
Action: Please contact your SA administrator.
An attempt to re-run the Build Plan, or another Build Plan,
results in the same error.
Perform one of the following actions to reset the iLO:
1. Connect to the iLO via a browser and, under Information
Diagnostics, press the Reset button to reset the iLO. Your
browser connection will be lost while the iLO resets.
2. Use the ssh” command to connect to the iLO and, at the
iLO prompt, type reset map1. Your ssh connection will
be lost while the iLO resets.
Troubleshoot OS Build Plan and build plan step failures 89