Backing up and restoring HP Insight Management 7.3 Central Management Server (Windows)

Technical white paper | HP Insight Management 7.3
RESOLUTION: Delete storage volume "\Virtual Disks\SPM\Volume4" in
storage array "" from the SPM catalog. This is
necessary to avoid the storage volume from being
reassigned to another resource. This can occur if, as
a post-backup activity the storage volume was added
to a newly created SPE and the SPE was associated to
a logical server. [ID001]
Checking \Virtual Disks\SPM\Volume8
Delete storage volume "\Virtual Disks\SPM\Volume8" in array "" from
SPM catalog...........................................................[INPUT]
ISSUE: Storage volume "\Virtual Disks\SPM\Volume8" is marked
as available in SPM. However Server WWN
50:01:43:80:02:A3:00:50 (VCEM, IN_USE) LUN 1 is
presented to storage volume "\Virtual
Disks\SPM\Volume8" in storage array "" and assigned
to VC Profile TC8phy-net01_13cd8ff7a90.
RESOLUTION: Delete storage volume "\Virtual Disks\SPM\Volume8" in
storage array "" from the SPM catalog. This is
necessary to avoid the storage volume from being
reassigned to another resource. This can occur if, as
a post-backup activity the storage volume was added
to a newly created SPE and the SPE was associated to
a logical server. [ID001]
Checking \Virtual Disks\SPM\Volume3...................................[OK]
Checking \Virtual Disks\SPM\Volume5...................................[OK]
Completed analysis of storage volumes that are not allocated to a
catalog-based SPE, but are presented to a WWN address within the range
managed by VCEM.
Analysis summary:
4 checks performed
2 actions needed
2 actions require input
0 errors
Analysis completed successfully. All issues should be resolved before taking
the "HP Storage Provisioning Manager Service" out of recovery mode. The "HP
Storage Provisioning Manager" service may be taken out of recovery mode by
editing the file "C:\Program Files (x86)\HP\Storage Provisioning
Manager\state\ApplicationConfig.xml" and setting the property <RecoveryMode>
to "Disabled".
The lsmanalyzer tool may be re-run at anytime using the following command
line syntax: "C:\Program Files\HP\Virtual Server Environment\bin\lsmAnalyzer"
--catalogSPE.
Completed analysis of storage volumes allocated to catalog-based SPEs.
Analysis completed successfully.
56