HP Insight Management Agent 8.40 Microsoft Windows Event ID and SNKP Traps Reference Guide

Server agents 102
NT Event ID: 1133 (Hex)0x8435046d (cpqsvmsg.dll)
Log Severity: Warning (2)
Log Message: Fan Removed. A hot-plug fan has been removed from the system.
SNMP Trap: cpqHe3FltTolFanRemoved - 6039 in CPQHLTH.MIB
Symptom: A Fault Tolerant Fan has been removed from the specified chassis and fan location.
Supporting SNMP Trap Data:
sysName
cpqHoTrapFlags
cpqHeFltTolFanChassis
cpqHeFltTolFanIndex
Supporting SNMP Trap Description: “The Fan Removed on Chassis [cpqHeFltTolFanChassis], Fan
[cpqHeFltTolFanIndex].”
NT Event ID: 1134 (Hex)0xc435046e (cpqsvmsg.dll)
Log Severity: Error (3)
Log Message: A Temperature Sensor Condition has been set to failed. The system will be shut down
due to this overheat condition.
SNMP Trap: cpqHe3TemperatureFailed - 6040 in CPQHLTH.MIB
Symptom: The temperature status has been set to failed in the specified chassis and location. The
system is shut down due to this condition.
Supporting SNMP Trap Data:
sysName
cpqHoTrapFlags
cpqHeTemperatureChassis
cpqHeTemperatureLocale
Supporting SNMP Trap Description: “Temperature Exceeded on Chassis [cpqHeTemperatureChassis],
Location [cpqHeTemperatureLocale].”
NT Event ID: 1135 (Hex)0x8435046f (cpqsvmsg.dll)
Log Severity: Warning (2)
Log Message: A Temperature Sensor Condition has been set to degraded. The system may or may
not shut down depending on the state of the thermal degraded action value '%6'.
SNMP Trap: cpqHe3TemperatureDegraded - 6041 in CPQHLTH.MIB
Symptom: The temperature status has been set to degraded in the specified chassis and location. The
server's temperature is outside of the normal operating range. The server is shut down if the
cpqHeThermalDegradedAction variable is set to shutdown (3).
Supporting SNMP Trap Data:
sysName
cpqHoTrapFlags
cpqHeThermalDegradedAction
cpqHeTemperatureChassis
cpqHeTemperatureLocale