HP Insight Management Agent 8.40 Microsoft Windows Event ID and SNKP Traps Reference Guide

Server agents 105
User Action: None.
Supporting SNMP Trap Data:
sysName
cpqHoTrapFlags
cpqSiHotPlugSlotChassis
cpqSiHotPlugSlotIndex
Supporting SNMP Trap Description: “Hot Plug Slot Board Inserted into Chassis
[cpqSiHotPlugSlotChassis], Slot [cpqSiHotPlugSlotIndex].”
NT Event ID: 1142 (Hex)0xc4350476 (cpqsvmsg.dll)
Log Severity: Error (3)
Log Message: Hot Plug PCI Board Failed. A hot plug PCI adapter has failed to power up. Insure the
board and all cables are installed correctly.
SNMP Trap: cpqSiHotPlugSlotPowerUpFailed - 2010 in CPQSINFO.MIB
Symptom: Hot Plug Slot Board Failed Power-Up. A Hot Plug Slot Board has failed to power up in the
specified chassis and slot.
User Action: Be sure the board and all cables are installed correctly, and that the board type and
revision are the same as the replaced board.
Supporting SNMP Trap Data:
sysName
cpqHoTrapFlags
cpqSiHotPlugSlotChassis
cpqSiHotPlugSlotIndex
cpqSiHotPlugSlotErrorStatus
Supporting SNMP Trap Description: “Hot Plug Slot Board Failed in Chassis
[cpqSiHotPlugSlotChassis], Slot [cpqSiHotPlugSlotIndex], Error [cpqSiHotPlugSlotErrorStatus].”
NT Event ID: 1143 (Hex)0x44350477 (cpqsvmsg.dll)
Log Severity: Information (1)
Log Message: Rack Name Changed.
SNMP Trap: cpqRackNameChanged - 22001 in CPQRACK.MIB
Symptom: The rack name has changed. This trap indicates that an agent or utility has changed the
name of the rack. Each of the server blades in each of the enclosure within the rack is updated to
reflect the new rack name. It may take several minutes for the rack name change to be propagated
throughout the entire rack.
User Action: None.
Supporting SNMP Trap Data:
sysName
cpqHoTrapFlags
cpqRackName
cpqRackUid
cpqRackSerialNum