HP Insight Management Agent 8.40 Microsoft Windows Event ID and SNKP Traps Reference Guide

Server agents 108
cpqRackCommonEnclosureTempLocation
cpqRackCommonEnclosureSparePartNumber
cpqRackCommonEnclosureTrapSequenceNum
Supporting SNMP Trap Description: “The enclosure [cpqRackCommonEnclosureName] temperature
sensor in rack [cpqRackName] has been set to failed.”
NT Event ID: 1148 (Hex)0x8435047c (cpqsvmsg.dll)
Log Severity: Warning (2)
Event Title: Rack Enclosure Overheating
Log Message: This trap indicates that an enclosure temperature sensor has been tripped indicating a
possible overheat condition.
SNMP Trap: cpqRackEnclosureTempDegraded - 22006 in CPQRACK.MIB
Symptom: The enclosure temperature status has been set to degraded. This trap indicates that an
enclosure temperature sensor has been tripped, indicating a possible overheat condition.
User Action: Shut down the enclosure and possibly the rack as soon as possible. Be sure that all fans
are working properly and that air flow in the rack has not been blocked.
Supporting SNMP Trap Data:
sysName
cpqHoTrapFlags
cpqRackName
cpqRackUid
cpqRackCommonEnclosureName
cpqRackCommonEnclosureSerialNum
cpqRackCommonEnclosureTempLocation
cpqRackCommonEnclosureSparePartNumber
cpqRackCommonEnclosureTrapSequenceNum
Supporting SNMP Trap Description: “The enclosure [cpqRackCommonEnclosureName] temperature
sensor in rack [cpqRackName] has been set to degraded.”
NT Event ID: 1149 (Hex)0x4435047d (cpqsvmsg.dll)
Log Severity: Information (1)
Event Title: Rack Enclosure Temperature Normal
Log Message: This trap indicates that an enclosure temperature sensor has returned to normal.
SNMP Trap: cpqRackEnclosureTempOk - 22007 in CPQRACK.MIB
Symptom: The enclosure temperature status has been set to OK. This trap indicates that an enclosure
temperature sensor has returned to normal.
User Action: None.
Supporting SNMP Trap Data:
sysName
cpqHoTrapFlags
cpqRackName
cpqRackUid