HP Insight Management Agent 8.40 Microsoft Windows Event ID and SNKP Traps Reference Guide

Server agents 109
cpqRackCommonEnclosureName
cpqRackCommonEnclosureSerialNum
cpqRackCommonEnclosureTempLocation
cpqRackCommonEnclosureSparePartNumber
cpqRackCommonEnclosureTrapSequenceNum
Supporting SNMP Trap Description: “The enclosure [cpqRackCommonEnclosureName] temperature
sensor in rack [cpqRackName] has been set to ok.”
NT Event ID: 1150 (Hex)0xc435047e (cpqsvmsg.dll)
Log Severity: Error (3)
Event Title: Rack Enclosure Fan Failed
Log Message: This trap indicates that an enclosure fan has failed and less than the minimum number
of fans in the redundant fan group are operating. This may result in overheating of the enclosure.
SNMP Trap: cpqRackEnclosureFanFailed - 22008 in CPQRACK.MIB
Symptom: The enclosure fan status has been set to failed. This trap indicates that an enclosure fan has
failed and that no other fans in the redundant fan group are operating. This may result in the
enclosure overheating.
User Action: Replace the fan as soon as possible.
Supporting SNMP Trap Data:
sysName
cpqHoTrapFlags
cpqRackName
cpqRackUid
cpqRackCommonEnclosureName
cpqRackCommonEnclosureSerialNum
cpqRackCommonEnclosureFanLocation
cpqRackCommonEnclosureFanSparePartNumber
cpqRackCommonEnclosureTrapSequenceNum
Supporting SNMP Trap Description: “The enclosure [cpqRackCommonEnclosureName] fan in rack
[cpqRackName] has been set to failed.”
NT Event ID: 1151 (Hex)0x8435047f (cpqsvmsg.dll)
Log Severity: Warning (2)
Event Title: Rack Enclosure Fan Degraded
Log Message: This trap indicates that an enclosure fan has failed but other fans in the redundant fan
group are still operating. This may result in overheating of the enclosure.
SNMP Trap: cpqRackEnclosureFanDegraded - 22009 in CPQRACK.MIB
Symptom: The enclosure fan status has been set to degraded. This trap indicates that an enclosure fan
has failed but that other fans in the redundant fan group are still operating. This may result in the
enclosure overheating.
User Action: Replace the fan as soon as possible.
Supporting SNMP Trap Data: