HP Insight Management Agent 8.40 Microsoft Windows Event ID and SNKP Traps Reference Guide

Server agents 114
Event Title: Rack Power Supply Inserted
Log Message: The power supply has been inserted.
SNMP Trap: cpqRackPowerSupplyInserted - 22017 in CPQRACK.MIB
Symptom: The power supply has been inserted.
User Action: None.
Supporting SNMP Trap Data:
sysName
cpqHoTrapFlags
cpqRackName
cpqRackUid
cpqRackPowerSupplyEnclosureName
cpqRackPowerSupplySerialNum
cpqRackPowerSupplyPosition
cpqRackPowerSupplyFWRev
cpqRackPowerSupplySparePartNumber
cpqRackCommonEnclosureSerialNum
cpqRackCommonEnclosureTrapSequenceNum
Supporting SNMP Trap Description: “The power supply [cpqRackPowerSupplyPosition] in enclosure
[cpqRackPowerSupplyEnclosureName] in rack [cpqRackName] has been inserted.”
NT Event ID: 1160 (Hex)0x84350488 (cpqsvmsg.dll)
Log Severity: Warning (2)
Event Title: Rack Power Subsystem Not Redundant
Log Message: The rack power subsystem is no longer in a redundant state.
SNMP Trap: cpqRackPowerSubsystemNotRedundant - 22018 in CPQRACK.MIB
Symptom: The rack power subsystem is no longer in a redundant state.
User Action: Replace any failed power supplies as soon as possible to return the system to a
redundant state.
Supporting SNMP Trap Data:
sysName
cpqHoTrapFlags
cpqRackName
cpqRackUid
cpqRackPowerEnclosureName
cpqRackCommonEnclosureSerialNum
cpqRackCommonEnclosureTrapSequenceNum
Supporting SNMP Trap Description: “The power subsystem in enclosure
[cpqRackPowerEnclosureName] in rack [cpqRackName] is no longer redundant.”
NT Event ID: 1161 (Hex)0x84350489 (cpqsvmsg.dll)
Log Severity: Warning (2)