HP Insight Management Agent 8.40 Microsoft Windows Event ID and SNKP Traps Reference Guide
Server agents 120
• cpqRackServerBladeEnclosureName
• cpqRackServerBladeName
• cpqRackServerBladePosition
• cpqRackServerBladeSparePartNumber
• cpqRackCommonEnclosureSerialNum
• cpqRackCommonEnclosureTrapSequenceNum
Supporting SNMP Trap Description: “Server blade [cpqRackServerBladeName] removed from
position [cpqRackServerBladePosition], in enclosure [cpqRackServerBladeEnclosureName], in rack
[cpqRackName].”
NT Event ID: 1171 (Hex)0x44350493 (cpqsvmsg.dll)
Log Severity: Information (1)
Event Title: Server Blade Inserted
Log Message: The server blade has been inserted from the enclosure.
SNMP Trap: cpqRackServerBladeInserted - 22029 in CPQRACK.MIB
Symptom: Server blade inserted. The server blade has been inserted into the enclosure.
User Action: None.
Supporting SNMP Trap Data:
• sysName
• cpqHoTrapFlags
• cpqRackName
• cpqRackUid
• cpqRackServerBladeEnclosureName
• cpqRackServerBladeName
• cpqRackServerBladePosition
• cpqRackServerBladeSparePartNumber
• cpqRackCommonEnclosureSerialNum
• cpqRackCommonEnclosureTrapSequenceNum
Supporting SNMP Trap Description: “Server blade [cpqRackServerBladeName] inserted into position
[cpqRackServerBladePosition], in enclosure [cpqRackServerBladeEnclosureName], in rack
[cpqRackName].”
NT Event ID: 1172 (Hex)0x84350494 (cpqsvmsg.dll)
Log Severity: Warning (2)
Event Title: Rack Power Subsystem Not Load Balanced
Log Message: The power subsystem is out of balance for this power enclosure.
SNMP Trap: cpqRackPowerChassisNotLoadBalanced - 22030 in CPQRACK.MIB
Symptom: Power subsystem not load balanced. The power subsystem is out of balance for this power
enclosure.
User Action: Check the power enclosure and power supplies. Replace any failed or degraded power
supplies. Add additional power supplies if needed.
Supporting SNMP Trap Data: