HP Insight Management Agent 8.40 Microsoft Windows Event ID and SNKP Traps Reference Guide

Server agents 121
sysName
cpqHoTrapFlags
cpqRackName
cpqRackUid
cpqRackCommonEnclosureName
cpqRackCommonEnclosureSerialNum
cpqRackCommonEnclosureSparePartNumber
cpqRackCommonEnclosureTrapSequenceNum
Supporting SNMP Trap Description: “Power subsystem not load balanced in enclosure
[cpqRackCommonEnclosureName], in rack [cpqRackName].”
NT Event ID: 1173 (Hex)0x84350495 (cpqsvmsg.dll)
Log Severity: Warning (2)
Event Title: Power Subsystem DC Power Problem
Log Message: There is a power subsystem DC power problem for this enclosure.
SNMP Trap: cpqRackPowerChassisDcPowerProblem - 22031 in CPQRACK.MIB
Symptom: Power subsystem DC power problem. There is a power subsystem DC power problem for
this power enclosure.
User Action: Check the power enclosure and power supplies. Replace any failed or degraded power
supplies.
Supporting SNMP Trap Data:
sysName
cpqHoTrapFlags
cpqRackName
cpqRackUid
cpqRackCommonEnclosureName
cpqRackCommonEnclosureSerialNum
cpqRackCommonEnclosureSparePartNumber
cpqRackCommonEnclosureTrapSequenceNum
Supporting SNMP Trap Description: “Power subsystem DC power problem in enclosure
[cpqRackCommonEnclosureName], in rack [cpqRackName].”
NT Event ID: 1174 (Hex)0x84350496 (cpqsvmsg.dll)
Log Severity: Warning (2)
Event Title: Power Subsystem Facility AC Power Problem
Log Message: The AC facility input power has been exceeded for this power enclosure.
SNMP Trap: cpqRackPowerChassisAcFacilityPowerExceeded - 22032 in CPQRACK.MIB
Symptom: Power subsystem AC facility input power exceeded for this power enclosure.
User Action: Check the power enclosure and power supplies. Replace any failed or degraded power
supplies.
Supporting SNMP Trap Data:
sysName