HP Insight Management Agent 8.40 Microsoft Windows Event ID and SNKP Traps Reference Guide

Server agents 127
Log Message: The agent could not deliver trap %1. The agent was unable to use Asynchronous
Management to deliver a trap. This can be caused by a failure in the Remote Access Service or by a
missing or invalid configuration. Use the Management Agent control panel to verify the Asynchronous
Management configuration settings. Use the Network control panel to verify the Remote Access
configuration. If this error persists, reinstalling the Server Agents or the Remote Access Service may
correct this error. For more information, see the Asynchronous Management documentation.
Event identifier: cpqsvmsg.dll - 3328 (Hex)0x84350d00 (Service Event)
Log Severity: Warning (2)
Log Message: Unable to allocate memory. This indicates a low memory condition. Rebooting the
system may correct this error.
Event identifier: cpqsvmsg.dll - 3329 (Hex)0x84350d01 (Service Event)
Log Severity: Warning (2)
Log Message: Could not read from the registry sub-key. This error can be caused by a corrupt registry
or a low memory condition. Rebooting the server may correct this error.
Event identifier: cpqsvmsg.dll - 3330 (Hex)0x84350d02 (Service Event)
Log Severity: Warning (2)
Log Message: Could not write the registry sub-key: “%1”. This error can be caused by a corrupt
registry or a low memory condition. Rebooting the server may correct this error.
Event identifier: cpqsvmsg.dll - 3331 (Hex)0x84350d03 (Service Event)
Log Severity: Warning (2)
Log Message: Could not read the registry sub-key: “%1”. This error can be caused by a corrupt
registry or a low memory condition. Rebooting the server may correct this error.
Event identifier: cpqsvmsg.dll - 3332 (Hex)0x84350d04 (Service Event)
Log Severity: Warning (2)
Log Message: Could not read the registry sub-key: “%1”. This error can be caused by a corrupt
registry or a low memory condition. Rebooting the server may correct this error.
Event identifier: cpqsvmsg.dll - 3333 (Hex)0x84350d05 (Service Event)
Log Severity: Warning (2)
Log Message: Could not read the registry sub-key: “%1”. This error can be caused by a corrupt
registry or a low memory condition. Rebooting the server may correct this error.
Event identifier: cpqsvmsg.dll - 3342 (Hex)0x84350d0e (Service Event)
Log Severity: Warning (2)
Log Message: The Remote Insight Agent got an unexpected error code while waiting for multiple
events. The data contains the error code.
Event identifier: cpqsvmsg.dll - 3345 (Hex)0x84350d11 (Service Event)
Log Severity: Warning (2)
Log Message: Remote Insight Board device driver not present. The Remote Insight Agent requires the
Remote Insight Board device driver (CPQSM2.SYS) to be installed. Install the driver from the latest
Software Support for Windows. If you do not have a Remote Insight Board in this system, disable the
Remote Insight Agent via the Management Agents Control Panel.