HP Insight Management Agent 8.40 Microsoft Windows Event ID and SNKP Traps Reference Guide

Storage agents 37
sysName
cpqHoTrapFlags
cpqScsiPhyDrvStatus
cpqScsiPhyDrvCntlrIndex
cpqScsiPhyDrvBusIndex
cpqScsiPhyDrvIndex
cpqScsiPhyDrvVendor
cpqScsiPhyDrvModel
cpqScsiPhyDrvFWRev
cpqScsiPhyDrvSerialNum
cpqScsiPhyDrvOsName
Supporting SNMP Trap Description: “Status is now [cpqScsiPhyDrvStatus].”
NT Event ID: 1075 (Hex)0x84350433 (cpqstmsg.dll)
Log Severity: Warning (2)
Event Title: Storage System Fan Status Change.
Log Message: The %6 %7 storage system connected to SCSI bus %5 of the controller in slot %4 has a
new status of %2.
SNMP Trap: cpqSs3FanStatusChange - 8008 in CPQSTSYS.MIB
Symptom: Storage System fan status change. The agent has detected a change in the Fan Status of a
storage system. The variable cpqSsBoxFanStatus indicates the current fan status.
User Action: If the fan status is degraded or failed, replace any failed fans.
Supporting SNMP Trap Data:
sysName
cpqHoTrapFlags
cpqSsBoxFanStatus
Supporting SNMP Trap Description: “Storage System fan status changed to [cpqSsBoxFanStatus].”
NT Event ID: 1076 (Hex)0xc4350434 (cpqstmsg.dll)
Log Severity: Error (3)
Event Title: Storage System Temperature Failure.
Log Message: The %6 %7 storage system connected to SCSI bus %5 of the controller in slot %4 has a
failed temperature status. Shut down the storage system as soon as possible.
SNMP Trap: cpqSs3TempFailed - 8009 in CPQSTSYS.MIB
Symptom: Storage System temperature failure. The agent has detected that a temperature status has
been set to failed. The storage system is shut down.
User Action: Shut down the storage system as soon as possible. Insure that the storage system
environment is being cooled properly and that no components are overheated.
Supporting SNMP Trap Data:
sysName
cpqHoTrapFlags
cpqSsBoxTempStatus