HP Insight Management Agent 8.40 Microsoft Windows Event ID and SNKP Traps Reference Guide

Storage agents 42
NT Event ID: 1145 (Hex)0xc4350479 (cpqstmsg.dll)
Log Severity: Error (3)
Event Title: External Array Logical Drive Status Change.
Log Message: Logical drive number %5 on array “%4” has a new status of %6.
SNMP Trap: cpqExtArrayLogDrvStatusChange - 16022 in CPQFCA.MIB
Symptom: External Array Logical Drive Status Change. This trap indicates that the agent has detected
a change in the status of an External Array logical drive. The variable cpqFcaLogDrvStatus indicates
the current logical drive status.
User Action: If the logical drive status is failed, examine the array for failed drives that need
replacement.
Supporting SNMP Trap Data:
sysName
cpqHoTrapFlags
cpqSsChassisName
cpqSsChassisTime
cpqFcaLogDrvBoxIndex
cpqFcaLogDrvIndex
cpqFcaLogDrvStatus
cpqFcaLogDrvOsName
cpqFcaLogDrvFaultTol
cpqFcaLogDrvSize
Supporting SNMP Trap Description: “Status is now [cpqFcaLogDrvStatus].”
NT Event ID: 1146 (Hex)0xc435047a (cpqstmsg.dll)
Log Severity: Error (3)
Event Title: External Array Physical Drive Status Change.
Log Message: The physical drive in port %5, bay %6 on array “%4” has a new status of %7.
SNMP Trap: cpqFca2PhyDrvStatusChange - 16016 in CPQFCA.MIB
Symptom: External Array Physical Drive Status Change. This trap indicates that the agent has detected
a change in the status of a physical drive. The variable cpaFcaPhyDrvStatus indicates the current
physical drive status.
User Action: If the physical drive status is threshExceeded(4), predictiveFailure(5) or failed(6), replace
the drive.
Supporting SNMP Trap Data:
sysName
cpqHoTrapFlags
cpqSsChassisName
cpqSsChassisTime
cpqFcaPhyDrvBusNumber
cpqFcaPhyDrvBay
cpqFcaPhyDrvStatus