HP Insight Management Agent 8.40 Microsoft Windows Event ID and SNKP Traps Reference Guide

Storage agents 53
Supporting SNMP Trap Data:
sysName
cpqHoTrapFlags
cpqFcTapeCntlrWWN
cpqFcTapeDriveScsiBus
cpqFcTapeDriveScsiTarget
cpqFcTapeDriveScsiLun
Supporting SNMP Trap Description: “Cleaning is needed for tape drive.”
NT Event ID: 1178 (Hex)0x8435049a (cpqstmsg.dll)
Log Severity: Warning (2)
Event Title: Fibre Channel Tape Drive Replace Cleaning Tape.
Log Message: The cleaning tape in the Fibre Channel tape drive on tape controller with world wide
name “%4”, SCSI bus %5, SCSI target %6, needs to be replaced.
SNMP Trap: cpqFcTapeDriveCleanTapeReplace - 16013 in CPQFCA.MIB
Symptom: Fibre Channel Tape Drive Cleaning Tape Needs Replacing. The agent has detected that an
autoloader tape unit has a cleaning tape that has been fully used and therefore needs to be replaced
with a new cleaning tape.
Supporting SNMP Trap Data:
sysName
cpqHoTrapFlags
cpqFcTapeCntlrWWN
cpqFcTapeDriveScsiBus
cpqFcTapeDriveScsiTarget
cpqFcTapeDriveScsiLun
Supporting SNMP Trap Description: “Cleaning tape needs replacing.”
NT Event ID: 1179 (Hex)0x8435049b (cpqstmsg.dll)
Log Severity: Warning (2)
Event Title: External Array Controller Active.
Log Message: The external controller in I/O slot %5 of array “%4” has become the active controller.
SNMP Trap: cpqFcaCntlrActive - 16014 in CPQFCA.MIB
Symptom: Fibre Array Controller Active. This trap indicates that the Storage Agent has detected that a
backup array controller in a duplexed pair has switched over to the active role. The variable
cpqFcaCntlrBoxIoSlot indicates the new active controller index.
User Action: Check the partner controller for problems. If this was the result of a user initiated switch-
over, no action is required.
Supporting SNMP Trap Data:
sysName
cpqHoTrapFlags
cpqSsChassisName
cpqSsChassisTime