HP Insight Management Agent 8.40 Microsoft Windows Event ID and SNKP Traps Reference Guide

Storage agents 59
Supporting SNMP Trap Description: “Storage system temperature status changed to
[cpqSsBackplaneTempStatus].”
NT Event ID: 1190 (Hex)0x843504a6 (cpqstmsg.dll)
Log Severity: Warning (2)
Event Title: Storage System Power Supply Status Change.
Log Message: An enclosure attached to port %5 of storage system “%4” has a new power supply
status of %7. The enclosure model is “%6”.
SNMP Trap: cpqSsExBackplanePowerSupplyStatusChange - 8024 in CPQSTSYS.MIB
Symptom: Storage System Power Supply Status Change. The agent has detected a change in the
power supply status of a storage system. The variable cpqSsBackplaneFtpsStatus indicates the current
status.
User Action: If the power supply status is degraded, restore power or replace the failed power supply.
Supporting SNMP Trap Data:
sysName
cpqHoTrapFlags
cpqSsChassisName
cpqSsChassisTime
cpqSsBackplaneIndex
cpqSsBackplaneVendor
cpqSsBackplaneModel
cpqSsBackplaneSerialNumber
cpqSsBackplaneFtpsStatus
Supporting SNMP Trap Description: “Storage system power supply status changed to
[cpqSsBackplaneFtpsStatus].”
NT Event ID: 1191 (Hex)0x843504a7 (cpqstmsg.dll)
Log Severity: Warning (2)
Event Title: SCSI Tape Library Status Change.
Log Message: The tape library with SCSI target %6 connected to SCSI bus %5 of the controller in slot
%4 has a new status of %7.
SNMP Trap: cpqTapeLibraryStatusChange - 5018 in CPQSCSI.MIB
Symptom: Tape Library Status Change. The Storage Agent has detected a change in the status of a
tape library. The current tape library status is indicated in the cpqTapeLibraryState variable.
Supporting SNMP Trap Data:
sysName
cpqHoTrapFlags
cpqTapeLibraryCntlrIndex
cpqTapeLibraryBusIndex
cpqTapeLibraryScsiIdIndex
cpqTapeLibraryLunIndex
cpqTapeLibraryName