HP Insight Management Agent 8.40 Microsoft Windows Event ID and SNKP Traps Reference Guide
Storage agents 73
Symptom: Physical Drive Status Change. This trap indicates that the agent has detected a change in
the status of a drive array physical drive. The variable cpqDaPhyDrvStatus indicates the current
physical drive status.
User Action: If the physical drive status is failed (3) or predictiveFailure (4), replace the drive.
Supporting SNMP Trap Data:
• sysName
• cpqHoTrapFlags
• cpqDaCntlrHwLocation
• cpqDaPhyDrvCntlrIndex
• cpqDaPhyDrvIndex
• cpqDaPhyDrvLocationString
• cpqDaPhyDrvType
• cpqDaPhyDrvModel
• cpqDaPhyDrvFWRev
• cpqDaPhyDrvSerialNum
• cpqDaPhyDrvFailureCode
• cpqDaPhyDrvStatus
• cpqDaPhyDrvBusNumber
Supporting SNMP Trap Description: “Physical Drive Status is now [cpqDaPhyDrvStatus].”
NT Event ID: 1217 (Hex)0x843504c1 (cpqstmsg.dll)
Log Severity: Warning (2)
Event Title: Drive Array Spare Drive Status Change.
Log Message: The spare drive in %4, %5 has a new status of %2.
SNMP Trap: cpqDa7SpareStatusChange - 3047 in CPQIDA.MIB
Symptom: Spare Drive Status Change. This trap indicates that the agent has detected a change in the
status of a drive array spare drive. The variable cpqDaSpareStatus indicates the current spare drive
status.
User Action: If the spare drive status is failed, replace the drive.
Supporting SNMP Trap Data:
• sysName
• cpqHoTrapFlags
• cpqDaCntlrHwLocation
• cpqDaSpareCntlrIndex
• cpqDaSparePhyDrvIndex
• cpqDaSpareStatus
• cpqDaSpareLocationString
• cpqDaSpareDrvBusNumber
Supporting SNMP Trap Description: “Spare Status is now [cpqDaSpareStatus].”