HP Insight Management Agent 8.40 Microsoft Windows Event ID and SNKP Traps Reference Guide

Storage agents 73
Symptom: Physical Drive Status Change. This trap indicates that the agent has detected a change in
the status of a drive array physical drive. The variable cpqDaPhyDrvStatus indicates the current
physical drive status.
User Action: If the physical drive status is failed (3) or predictiveFailure (4), replace the drive.
Supporting SNMP Trap Data:
sysName
cpqHoTrapFlags
cpqDaCntlrHwLocation
cpqDaPhyDrvCntlrIndex
cpqDaPhyDrvIndex
cpqDaPhyDrvLocationString
cpqDaPhyDrvType
cpqDaPhyDrvModel
cpqDaPhyDrvFWRev
cpqDaPhyDrvSerialNum
cpqDaPhyDrvFailureCode
cpqDaPhyDrvStatus
cpqDaPhyDrvBusNumber
Supporting SNMP Trap Description: “Physical Drive Status is now [cpqDaPhyDrvStatus].”
NT Event ID: 1217 (Hex)0x843504c1 (cpqstmsg.dll)
Log Severity: Warning (2)
Event Title: Drive Array Spare Drive Status Change.
Log Message: The spare drive in %4, %5 has a new status of %2.
SNMP Trap: cpqDa7SpareStatusChange - 3047 in CPQIDA.MIB
Symptom: Spare Drive Status Change. This trap indicates that the agent has detected a change in the
status of a drive array spare drive. The variable cpqDaSpareStatus indicates the current spare drive
status.
User Action: If the spare drive status is failed, replace the drive.
Supporting SNMP Trap Data:
sysName
cpqHoTrapFlags
cpqDaCntlrHwLocation
cpqDaSpareCntlrIndex
cpqDaSparePhyDrvIndex
cpqDaSpareStatus
cpqDaSpareLocationString
cpqDaSpareDrvBusNumber
Supporting SNMP Trap Description: “Spare Status is now [cpqDaSpareStatus].”