HP Insight Management Agent 8.40 Microsoft Windows Event ID and SNKP Traps Reference Guide

Storage agents 80
Log Message: The IDE Agent could not create its main thread of execution. The data contains the
error code.
Event identifier: cpqstmsg.dll - 3596 (Hex)0x84350e0c (Service Event)
Log Severity: Warning (2)
Log Message: The IDE Agent main thread did not terminate properly. The data contains the error
code.
Event identifier: cpqstmsg.dll - 3597 (Hex)0x84350e0d (Service Event)
Log Severity: Warning (2)
Log Message: The IDE Agent got an unexpected error code while waiting for an event. The data
contains the error code.
Event identifier: cpqstmsg.dll - 3598 (Hex)0x84350e0e (Service Event)
Log Severity: Warning (2)
Log Message: The IDE Agent got an unexpected error code while waiting for multiple events. The
data contains the error code.
Event identifier: cpqstmsg.dll - 3599 (Hex)0x84350e0f (Service Event)
Log Severity: Warning (2)
Log Message: The IDE Agent did not respond to a request. The data contains the error code.
Event identifier: cpqstmsg.dll - 3600 (Hex)0x84350e10 (Service Event)
Log Severity: Warning (2)
Log Message: The IDE Agent received an unknown action code from the service. The data contains
the action code.
Event identifier: cpqstmsg.dll - 4097 (Hex)0x84351001 (Service Event)
Log Severity: Warning (2)
Log Message: Could not read from the registry subkey. This error can be caused by a corrupt registry
or a low memory condition. Rebooting the server may correct this error.
Event identifier: cpqstmsg.dll - 4098 (Hex)0x84351002 (Service Event)
Log Severity: Warning (2)
Log Message: Could not write the registry subkey: “%1”. This error can be caused by a corrupt
registry or a low memory condition. Rebooting the server may correct this error.
Event identifier: cpqstmsg.dll - 4099 (Hex)0x84351003 (Service Event)
Log Severity: Warning (2)
Log Message: Could not read the registry subkey: “%1”. This error can be caused by a corrupt
registry or a low memory condition. Rebooting the server may correct this error.
Event identifier: cpqstmsg.dll - 4100 (Hex)0x84351004 (Service Event)
Log Severity: Warning (2)
Log Message: Could not read the registry subkey: “%1”. This error can be caused by a corrupt
registry or a low memory condition. Rebooting the server may correct this error.
Event identifier: cpqstmsg.dll - 4101 (Hex)0x84351005 (Service Event)