HP Insight Management Agent 8.40 Microsoft Windows Event ID and SNKP Traps Reference Guide

Server agents 90
[cpqHeFltTolPowerSupplyModel], Serial Num [cpqHeFltTolPowerSupplySerialNumber], Firmware
[cpqHeFltTolPowerSupplyFirmwareRev].”
NT Event ID: 1072 (Hex)0x84350430 (cpqsvmsg.dll)
Log Severity: Warning (2)
Log Message: The frequency of memory errors is high enough such that tracking of correctable
memory errors has been temporarily disabled.
SNMP Trap: cpqHe3CorrectableMemoryLogDisabled - 6016 in CPQHLTH.MIB
Symptom: Correctable memory error tracking disabled. The frequency of errors is so high that the
error tracking logic has been temporarily disabled. The cpqHeCorrMemLogStatus variable indicated
the current tracking status.
Supporting SNMP Trap Data:
sysName
cpqHoTrapFlags
cpqHeCorrMemLogStatus
Supporting SNMP Trap Description: “Too many memory errors - tracking now disabled.”
NT Event ID: 1082 (Hex)0xc435043a (cpqsvmsg.dll)
Log Severity: Error (3)
Log Message: A Thermal Temperature Condition has been set to failed. The system will be shut down
due to this thermal condition.
SNMP Trap: cpqHe3ThermalTempFailed - 6017 in CPQHLTH.MIB
Symptom: The temperature status has been set to failed. The system is shut down due to this thermal
condition.
Supporting SNMP Trap Data:
sysName
cpqHoTrapFlags
Supporting SNMP Trap Description: “System will be shut down due to this thermal condition.”
NT Event ID: 1083 (Hex)0x8435043b (cpqsvmsg.dll)
Log Severity: Warning (2)
Log Message: The Thermal Temperature Condition has been set to degraded. The system may be shut
down due to this thermal condition depending on the state of the thermal degraded action value '%4'.
SNMP Trap: cpqHe3ThermalTempDegraded - 6018 in CPQHLTH.MIB
Symptom: The temperature status has been set to degraded. The server's temperature is outside of the
normal operating range. The server is shut down if the
cpqHeThermalDegradedAction variable is set to shutdown (3).
Supporting SNMP Trap Data:
sysName
cpqHoTrapFlags
cpqHeThermalDegradedAction
Supporting SNMP Trap Description: “Temperature out of range. Shutdown may occur.”
NT Event ID: 1084 (Hex)0x4435043c (cpqsvmsg.dll)