HP Insight Management Agent 8.40 Microsoft Windows Event ID and SNKP Traps Reference Guide

Server agents 95
Supporting SNMP Trap Data:
sysName
cpqHoTrapFlags
Supporting SNMP Trap Description: “Server [sysName], Remote Insight/Integrated Lights-Out
interface error.”
NT Event ID: 1112 (Hex)0x84350458 (cpqsvmsg.dll)
Log Severity: Warning (2)
Log Message: The Remote Insight Board has detected that the battery is disconnected.
SNMP Trap: cpqSm2BatteryDisconnected - 9007 in CPQSM2.MIB
Symptom: Remote Insight Battery Disconnected. The Remote Insight battery cable has been
disconnected.
Supporting SNMP Trap Data:
sysName
cpqHoTrapFlags
Supporting SNMP Trap Description: “Remote Insight battery disconnected.”
NT Event ID: 1113 (Hex)0x84350459 (cpqsvmsg.dll)
Log Severity: Warning (2)
Log Message: The Remote Insight Board has detected that the keyboard cable is disconnected.
SNMP Trap: cpqSm2KeyboardCableDisconnected - 9008 in CPQSM2.MIB
Symptom: Keyboard Cable Disconnected. The Remote Insight keyboard cable has been disconnected.
Supporting SNMP Trap Data:
sysName
cpqHoTrapFlags
Supporting SNMP Trap Description: “Remote Insight keyboard cable disconnected.”
NT Event ID: 1114 (Hex)0x8435045a (cpqsvmsg.dll)
Log Severity: Warning (2)
Log Message: A processor has crossed the threshold of allowable corrected errors. The processor
should be replaced.
SNMP Trap: cpqSeCpuThresholdPassed - 1005 in CPQSTDEQ.MIB
Symptom: This trap is sent when an internal processor error threshold has been passed on a particular
processor, causing it to become degraded. This trap is sent when cpqSeCpuThreshPassed transitions
from false to true.
Supporting SNMP Trap Data:
sysName
cpqHoTrapFlags
cpqSeCpuSlot
cpqSeCpuSocketNumber
cpqSeCpuSpeed
cpqSeCpuExtSpeed