User Service Guide, Second Edition - HP Integrity BL60p Server Blade
Removing and Replacing Components
Removing and Replacing the Airflow Guide
Chapter 4
52
CAUTION If you are converting the server blade from a two-processor system to a one-processor
system, you need to install the airflow guide blocker onto the airflow guide. Failure to
install the airflow blocker causes improper air flow to the processor, and the CPU
will overheat and fail. Refer to Figure 4-12.
Figure 4-12 Airflow Guide Blocker
Step 2. Lower the airflow guide on top of the processors, with the flanges going between the fans on the fan
assembly. Route the wires into the slots on the airflow guide. Refer to Figure 4-12 and Figure 4-13.
Figure 4-13 Replacing the Airflow Guide
Airflow guide
Airflow guide
blocker
Flanges
Airflow guide
Flanges