User Service Guide, Second Edition - HP Integrity BL60p Server Blade

Troubleshooting
Supported Configurations
Chapter 5
84
Step 4. Select a, then a threshold filter number to filter events to desired level.
MP:SL (+,-,<CR>,D, F, L, J, H, K, T, A, U, ? for Help, Q or Ctrl-B to Quit) >a
Alert Level Threshold Filter:
1 : Major Forward Progress
2 : Informational
3 : Warning
5 : Critical
7 : Fatal
Enter alert level threshold or [Q] to quit filter setup: 3
-> Alert threshold level 3 filter will be applied.
Step 5. Select v, then t to change the display to text mode:
Display Mode Configuration:
H - Hex mode
Current -> K - Keyword mode
T - Text mode
Enter new value, or [Q] to Quit:
Step 6. To decode the blinking state of system LED, review the entire SEL and look at events with alert
level 2 and above.
For example:
Log Entry 24: 14 Feb 2003 15:27:02
Alert Level 3: Warning
Keyword: Type-02 1b0800 1771520
Hot Swap Cage: SCSI cable removed
Logged by: BMC; Sensor: Cable / Interconnect - SCSI ChExt Cable
Data1: Device Removed/Device Absent
0x203E4D0AC6020220 FFFF0008F61B0300
Log Entry 73: 00:00:12
Alert Level 3: Warning
Keyword: Type-02 050301 328449
The server's built-in sensors have detected an open chassis door.
Logged by: BMC; Sensor: Physical Security - Chassis Open
Data1: State Asserted
0x200000000C020570 FFFF010302050300
Supported Configurations
This subsection provides examples of how to use the MP to acquire configuration information for
troubleshooting purposes. It also provides a system build-up procedure.
For a list of all FRUs in the server blade, with their corresponding part numbers, refer to Appendix A, “Parts
Information,” on page 99.
System Build-Up Troubleshooting Procedure
Use this procedure only when the system powers on and remains powered on but does not enter into or pass
POST, or does not boot to EFI menu.
Step 1. Remove the access panel to gain access to internal FRUs. Refer to “Removing the Server Blade
Access Panel” on page 47.