User Service Guide, Second Edition - HP Integrity BL60p Server Blade
Troubleshooting
Supported Configurations
Chapter 5
85
Step 2. Remove all of the HDDs from the front of the chassis. Refer to “Removing a Hot-Plug SCSI Hard
Drive” on page 42.
Step 3. Remove the memory DIMMs. Refer to “Removing a DIMM” on page 55.
Step 4. Remove the processors. Refer to “Removing a Processor” on page 58.
Step 5. Replace the server blade in the enclosure. The server blade (and MP) powers on.
Step 6. Enter the DF command from the MP Console Menu. The following FRU IDs display:
CM> DF
Display FRU Information Menu:
S - Specific FRU
A - All available FRUs
V - Display Mode: Text
Step 7. Enter S to show the FRU IDs. The following displays:
FRU IDs:
--------
0001-Comm Module 0002-Disk Backplane
0003-Mezzanine Board 0000-Motherboard
If you do not see all of the above FRU IDs, then concentrate on the missing FRU ID(s). The
following alert (IPMI) event displays for this action, as read from the SEL:
Log Entry 4: Dec 2005 00:00:09
Alert Level 7: Fatal
Keyword: Type-02 257100 2453760
Missing FRU device - DIMM0A
Logged by: Baseboard Management Controller,
Sensor: Entity Presence
0x2000000009020050 FF01807115250300
If you do not get the above Alert Level 7 (IPMI) event, but get another high level alert, replace the
server blade.
Step 8. Add at least one rank of memory DIMMs.
Step 9. Enter the DF command. The following displays:
The following displays:
Display FRU Information Menu:
S - Specific FRU
A - All available FRUs
V - Display Mode: Text
Step 10. Enter S to show the FRU IDs. The following displays (one rank of DIMMs installed):
FRU IDs:
--------
0001-Comm Module 0002-Disk Backplane 0003- Mezzanine Board
0128-DIMM0A 0129-DIMM0B 0000-Motherboard
If you do not see all of the above FRU IDs then concentrate on the missing FRU ID(s). The following
alert (IPMI) event displays for this action, as read from the SEL: