User Service Guide, Second Edition - HP Integrity BL60p Server Blade
Appendix C
Utilities
Management Processor Command Interface
154
• - — View the previous block (backward in time)
• Enter (<CR>) — View the next block in the previously selected direction (forward or backward in time)
• D — Dump the entire log for capture or analysis
•F — First entry
•L — Last entry
• J — Jump to entry number __
• V — View mode configuration (text, keyword, hex)
• ? — Display this help menu
•Q — Quit
Table C-8 defines alert (or severity) levels.
Security Options
SO: Configure security options and access control
Use this command to modify the security options of MP. These are:
• Login timeouts
• Allowed password faults
• Allow fw upgrade over pci
• Allow mp reset from ipmi
• SSL certificate generation
•SSH key pair generation
Login timeout: is effective on all ports, including the local port, and timeout value is the same for all ports.
However, the local port cannot be disconnected like other ports on login timeout. So if a local port user sits at
the 'MP login:' prompt, nothing happens even if a timeout occurs. But if a local port user enters a login name,
and then sits at the 'MP password:' prompt, if timeout occurs at this stage, this login is cancelled and you go
back to the 'MP login:' prompt.
System Status
SS: Displays the status of the system processors
Table C-8 Alert Levels
Severity Definition
0 Minor forward progress
1 Major forward progress
2Informational
3 Warning
5 Critical
7Fatal