User Service Guide, Second Edition - HP Integrity BL60p Server Blade

Console Setup and Connection
Configuring iLO MP Access
Appendix D
159
CAUTION Disconnect the local I/O cable from the port when not in use. The port and connector are not
intended to provide a permanent connection.
Figure D-1 Connecting the Local I/O Cable to the Server Blade
CAUTION On the local I/O cable, locking buttons are located on the sides of the server blade connector.
Always be sure to squeeze the locking buttons on the local I/O cable connector before
disconnecting the cable from the I/O port. Failure to do so can result in damage to the port.
Connecting a Terminal to the Server Blade
Use the following procedure to establish a connection from your server to your terminal (or emulator device).
CAUTION Disconnect the local I/O cable from the port when not in use. The port and connector are not
intended to provide a permanent connection.
Step 1. Connect the standard DB9 RS-232 cable to the RS232 port on the I/O cable. Refer to Figure D-2
Step 2. Connect the other end of the RS232 cable to your terminal device (1).