User Service Guide, Second Edition - HP Integrity BL60p Server Blade

Introduction
Safety Information
Chapter 1
22
Figure 1-3 Server Blade CPU and DIMM Slot Locations
Safety Information
Use care to prevent injury and equipment damage when performing removal and replacement procedures.
Voltages might be present within the server. Many assemblies are sensitive to damage by electrostatic
discharge.
Follow the procedures listed below to ensure safe handling of components, to prevent injury, and to prevent
damage to the HP server:
When removing or installing any server component, follow the instructions provided in this guide
If installing a hot-swappable or hot-pluggable component when power is applied (fans are running),
reinstall the server cover immediately to prevent overheating
If installing a hot-pluggable component, software intervention is required prior to removing the
component.
If installing an assembly that is neither hot-swappable, nor hot-pluggable, disconnect the power cable
from the server external power connector
WARNING Ensure that the system is powered down and all power sources have been
disconnected from the server prior to working with the server (unless you are
removing or installing a hot-swappable or hot-pluggable component).
Voltages are present at various locations within the server whenever an AC
power source is connected. This voltage is present even when the main power
switch is in the off position.
Failure to observe this warning could result in personal injury or damage to
equipment.
CPU 0
CPU 1
Front of Server
DIMM slot 0A
DIMM slot 0B
DIMM slot 1A
DIMM slot 1B