HP Integrity BL860c i2, BL870c i2 & BL890c i2 Server Blade User Service Guide
Drive paths in UEFI
Devices in the server blade are represented by device paths in the UEFI shell. Each internal SAS
drive could be configured either as:
• RAID mode
• HBA (raw) mode
NOTE: A SAS drive in RAID mode is identified by "Scsi" in the device path A SAS drive in HBA
mode is identified by “SAS” in the device path.
NOTE: Unlike parallel SCSI, you cannot correlate UEFI device paths to internal SAS disk drive
bays with SAS regardless of RAID/HBA mode. The UEFI device paths currently do not contain any
information that could be used to determine the physical location of the drives.
Path examplePath formatDevice
PcieRoot(0x30304352)/Pci(0x2,0x0)/
Pci(0x0,0x0)/Scsi(0x0,0x0)
UIDPCIe root bridge device path
node
(RAID mode)
PcieRoot(0x30304352)/Pci(0x2,0x0)/Pci(0x0,0x0)
/SAS(0x5000C500037688B9,0x0,0x1,NoTopology,
0,0,0,0x0)
(HBA mode)
PcieRoot(0x30304352)/Pci(0x2,0x0)/Pci(0x0,0x0)/
Scsi(0x0,0x0)
/HD(1,GPT,27C34F01-9F1E-11DE-A0BB-AA000400FEFF)
HD
(Partition,Type,Signature)
Hard drive partition device
path
(RAID mode)
PcieRoot(0x30304352)/Pci(0x2,0x0)/Pci(0x0,0x0)/
SAS(0x5000C500037688B9,0x0,0x1,NoTopology,0,0,0,
0x0) )/HD
(1,GPT,27C34F01-9F1E-11DE-A0BB-AA000400FEFF)
(HBA mode)
PcieRoot(0x30304352)/Pci(0x1D,0x7)/
USB(0x3,0x0)/CDROM(0x1)
CDROM(Entry)CD-ROM / DVD-ROM
partition device path
NOTE: Everything after "Scsi" or "SAS" in the output can vary because each SAS drive/partition
is unique
Using the Boot Maintenance Manager
This menu allows you to change various boot options. The Boot Maintenance Manager Contains
the following submenus:
• Boot Options
• Driver Options
• Console Options
• Boot From File
• Set Boot Next Value
• Set Time Out Value
• Reset System
142 Utilities