HP Integrity iLO 3 Operations Guide

Additional help is available at the help prompt. Given a topic or command, more detailed help is
available.
When issued in command mode, HE displays the list of the MP Command Mode commands
available according to the level of the MP Command Mode of the requestor (Operator or
Administrator) and the MP mode (Normal or Manufacturing).
HE also displays the MP Help: Command Menu List of detailed help information in response
to a topic or command at the help prompt.
Command line usage and scripting:
HE [ -topic | command ] [ -nc ]
HE -?
ID: System information settings
Command access level: MP configuration access
The ID command displays and modifies the following:
Host System Configuration
Asset Tag information
Command line usage and scripting:
ID [ { -host }
[ -tag <text> } ] [ -nc ]
ID -?
IT: Modify MP inactivity timers
Command access level: MP configuration access
The IT command prevents sessions on the system from being inadvertently left open. When you
initiate an iLO 3 MP command, other users are prohibited from running any commands until the
first command has been completed or until it times out. Command interface inactivity timeout
specifies that timeout value. This prevents a user from inadvertently keeping iLO 3 locked in a
command, preventing other users from running iLO 3 MP commands.
The inactivity timeout effects how long a user can stay inactive within a command in the text user
interface before they are placed back at the command prompt. There is no session timeout on the
Integrity iLO 3 text interfaces.
NOTE: The iLO 3 MP command interface inactivity timeout cannot be deactivated.
Use the flow control timeout to prevent any user who is using a terminal that does not obey flow
control from locking the system out from other users.
The following are IT command parameters:
iLO 3 inactivity timeout 1 to 30 minutes (default is 3 minutes).
Flow control timeout 0 to 60 minutes. If the flow control timeout is set to zero, no
timeout is applied. A mirroring flow control condition ceases
when no flow control condition exists on any port. This
timeout prevents mirrored flow control from blocking other
ports when inactive.
Command line usage and scripting:
IT [ -command <n> ] [ -flow <n> ] [ -nc ]
IT -?
See also: SA
LC: LAN configuration usage
Command access level: MP configuration access
56 Using iLO 3