Installation Instructions - HP Server Static Mount Kit AB293A for NEBS 2000 Rack
HP Server Static Mount Kit for NEBS 2000 Rack – Installation Instructions
Installation Procedure
Chapter 1
6
Step 6. Loosely install two chassis rear mount brackets to the back of the rear rack columns as shown in
Figure 1-3. Attach each chassis rear mount bracket to the corresponding retainer bar using two T25
screws, but do not tighten the screws at this time.
Step 7. Install the server. Slide the server into position on the rails and secure it to the front columns with
T25 screws threaded into the front retainer bars.
Figure 1-4Insert the Server into the Rack
Step 8. From the rear of the rack, secure cable routing mount brackets on the rear of the server chassis to
the chassis rear mount brackets using T25 screws as shown in Figure 1-5. Then tighten the screws
that secure the chassis rear mount brackets to the columns and retainer bars. (These screws were
left loose in step 6.)
rckmnt1
T25
Screws