Site Preparation Guide, Third Edition - HP Integrity cx2600
System Specifications
Environmental Specifications
Chapter 2
18
PCI/Mass Storage Section Cooling
One 80 mm, dual blade fan pushes airflow through the PCI card cage. The fan is controlled by the room
ambient temperature and runs at the speed necessary to maintain proper internal temperature throughout
the PCI card cage.
Typical Power Dissipation and Cooling
The system configurations shown in Table 2-5 are typical of most systems and show the power and cooling
values required for the listed components. These power and cooling values are considered typical and not
maximum for the configurations shown.
Table 2-5 Typical Configuration Power Consumption Values
CPU Memory
PCI Cards
(assuming
10W each)
Hard
Disk
Drives
Typical
Power
Typical
Cooling
Qty Gigabytes Qty Qty Watts BTU/Hr
11 GB
(4 DIMMs @
256 MB ea.)
113601144
124 GB
(12 DIMMs @
2 GB ea.)
213851212
224 GB
(12 DIMMs @
2 GB ea.)
325751809
224 GB
(12 DIMMs @
2 GB ea.)
425961876
224 GB
(12 DIMMs @
2 GB ea.)
125311673
224 GB
(12 DIMMs @
2 GB ea.)
235741809
224 GB
(12 DIMMs @
2 GB ea.)
335961876
224 GB
(12 DIMMs @
2 GB ea.)
436171944