User Service Guide, Third Edition - HP Integrity cx2620 Server
EFI Error and Warning Messages
EFI error and warning messages are displayed on the console as part of the boot process. They
can also be retrieved using the EFI info warnings command. Table 5-14 lists possible error
messages.
Table 5-14 EFI Error and Warning Messages
Description/SolutionMessageError Number
Incorrect I/O configuration. Contact the HP
Support Center for assistance.
Insufficient resources to assign to one or more
I/O devices
2
Incorrect I/O configuration. Contact the HP
Support Center for assistance.
Unexpected hardware I/O configuration4
Update BMC firmware.No BMC installed on the platform7
Check system logs for errors. Replace the system
board.
BMC cannot be accessed8
Communication with the BMC failed. Check
power. Replace the system board.
One or more BMC ports failed9
Clear the SEL.BMC system event log is full10
Contact the HP Support Center for assistance.Platform silicon-controlled rectifier (SCR) is bad11
Communication with the BMC failed. Replace the
system board.
Set time to BMC SEL failed12
Communication with the BMC failed. Replace the
system board.
SEL get info failed
13
Communication with the BMC failed. Replace the
system board.
Initial BMC SEL event failed14
Communication with the BMC failed. Replace the
system board.
Update of BMC buffered data failed15
Communication with the BMC failed. Replace the
system board.
All advanced configuration and power interface
(ACPI) BMC ports bad
16
Communication with the BMC failed. Replace the
system board.
Read error on BMC token17
Communication with the BMC failed. Replace the
system board.
BMC token transmit checksum error
18
Communication with the BMC failed. Replace the
system board.
Error writing BMC token on download19
Communication with the BMC failed. Replace the
system board.
Non-volatile Memory (NVM) token access error20
Communication with the BMC failed. Replace the
system board.
BMC token write error during NVM write
through
21
Communication with the BMC failed. Replace the
system board.
Error reading BMC token on upload to NVM22
Communication with the BMC failed. Replace the
system board.
Error reading BMC first boot token23
Reflash firmware.Primary field interoperability testing (FIT) failed24
Reflash firmware.Secondary FIT failed25
Reflash firmware.Processor abstraction layer (PAL) A warning;
One copy of PAL is bad
26
Error Messages 135