Table 5-14 EFI Error and Warning Messages (continued)
Description/SolutionMessageError Number
Update firmware.PAL A warning; PAL is not compatible with at
least 1 CPU
27
Reseat DIMMs; if error persists replace bad
DIMMs.
Memory errors detected and Page Deallocation
Table (PDT) is disabled
28
Information only, no action required.Memory required reinterleave to get a good
page 0
30
Information only, no action required.One or more ranks have chipspare disabled31
Check memory installation. Match DIMM part
numbers within each quad.
One or more memory ranks are mismatched or
deallocated
33
Check memory installation. DIMMs must be
installed with smallest capacity in the first quad,
an equal or larger capacity in the second quad, and
an equal or larger capacity in the third quad.
Memory deallocated because of a loading error34
Check memory installation. DIMMs must be
installed with smallest capacity in the first quad,
an equal or larger capacity in the second quad, and
an equal or largest capacity in the third quad.
Memory load order error35
Clear with pdt clear command in the EFI Shell.
The PDT is full36
Check processor installation. Verify installation
and that identical processors have been installed.
At least one CPU has bad fixed core ratio37
Processor failure. Verify installation and replace
processor. Contact the HP Support Center for
assistance.
All CPUs were slated for compatibility
deconfiguration
38
Check processor installation and match CPU part
numbers. CPUs must be identical.
Incompatible CPUs detected39
Check processor installation. Match CPU part
numbers. CPUs must be identical. This always
causes a stopboot.
CPUs installed with mixed cache sizes40
Check processor installation and match CPU part
numbers. CPUs must be identical.
CPUs installed with mixed steppings41
Check processor installation and match CPU part
numbers. CPUs must be identical.
All CPUs are overclocked42
Check processor installation and match CPU part
numbers. CPUs must be identical.
At least one (1) CPU is overclocked43
Check processor installation and match CPU part
numbers. CPUs must be identical.
Monarch changed to lowest stepping CPU44
Reload processors in the correct order.CPUs loaded in wrong order46
Information only, no action required.SAL NVM cleared48
Information only, no action required.EFI NVM cleared49
Reboot the server. If the error message is repeated,
contact the HP Support Center for assistance.
EFI NVM failed50
Check and verify processor installation. Replace
the processor that was deconfigured.
CPU deconfigured by SAL_B51
One or more firmware components (FW, BMC,
iLO MP) is out of date. Update firmware as
appropriate.
A ROM revision is inconsistent with FIT or
REVBLOCK
52